The maths is the same everywhere — MTBF, MTTR, availability, failure rates. What changes between industries is which numbers get reported, which standards govern them, and what a failure actually costs. This page maps each sector to its metrics, standards, and the calculators that produce them.

Discrete manufacturing

Reliability is judged by throughput. A stoppage costs lost production, so maintenance performance is reported as OEE and as MTBF / MTTR per asset, and improvement work is prioritised with Pareto analysis of downtime causes.

MetricWhat it tells you
OEEAvailability × performance × quality — where the capacity is lost
MTBF / MTTRHow often an asset stops, and how long it stays down
Planned maintenance %Share of maintenance hours that were scheduled rather than reactive
PM compliancePreventive tasks completed on time

Standards and frameworks: ISO 22400-2 (manufacturing KPIs, including OEE), ISO 55000 series (asset management), Total Productive Maintenance (TPM), and SAE JA1011 for reliability-centred maintenance.

ToolsOEEMTBFMTTRPareto ChartCost of Downtime

Automotive

Automotive reliability is driven by the supply chain: customers require suppliers to prove process capability and measurement capability before parts ship, and to manage risk through FMEA.

RequirementCommonly used threshold
Process capability (ongoing)Cpk ≥ 1.33
Process performance (initial, PPAP)Ppk ≥ 1.67
Gage R&R (% of total variation)< 10% acceptable · 10–30% conditional · > 30% not acceptable

The AIAG & VDA FMEA Handbook (2019) replaced the RPN with Action Priority (AP), which weights severity first — so a high-severity failure mode can need action even with a modest RPN. Customer specifics override these defaults; always check the customer-specific requirements.

Standards and frameworks: IATF 16949, the AIAG core tools (APQP, PPAP, FMEA, MSA, SPC), and the AIAG & VDA FMEA Handbook.

ToolsProcess CapabilityGage R&RFMEA / RPNControl ChartDPMO

Aerospace & aviation

Safety sets the requirements. Designs are analysed for failure probability per flight hour, and maintenance programmes are built from failure-mode analysis rather than fixed calendars.

MetricUse
Failure rate per flight hourSafety assessment against probability objectives
MTBURMean time between unscheduled removals — drives spares and maintenance cost
Dispatch reliabilityShare of departures without a technical delay or cancellation
Weibull βWhether a component is wearing out (β > 1) or failing randomly (β ≈ 1)

Standards and frameworks: AS9100 (quality management), SAE ARP4754 and ARP4761 (system development and safety assessment), MSG-3 (maintenance programme development), and MIL-HDBK-217F (electronic reliability prediction, still widely referenced).

ToolsWeibull AnalysisReliability R(t)Failure RateSpare Parts

Energy & utilities

Distribution utilities report reliability from the customer's side — how often supply was interrupted and for how long — using the indices defined in IEEE 1366.

SAIFI — interruption frequency
Total customer interruptions ÷ total customers served
SAIDI — interruption duration
Total customer interruption minutes ÷ total customers served
CAIDI — average restoration time
SAIDI ÷ SAIFI

CAIDI is effectively the network's MTTR as a customer experiences it; SAIFI is the inverse of the time between interruptions. Generation assets are tracked with forced-outage rates, and asset-heavy utilities often organise the whole programme around ISO 55000.

Standards and frameworks: IEEE 1366, NERC reliability standards (North America), ISO 55000, and ISO 14224 for structured equipment failure data.

ToolsAvailabilitySystem ReliabilityMTTR

Data centres & IT

Availability is sold as a promise, so it is expressed in “nines” and in allowed downtime. Physical infrastructure relies on redundancy (N+1, 2N); software services manage reliability with service-level objectives and error budgets.

AvailabilityDowntime per yearDowntime per 30 days
99%87.6 h7.2 h
99.9%8.76 h43.2 min
99.99%52.6 min4.32 min
99.999%5.26 min25.9 s

An SLO of 99.9% over 30 days leaves an error budget of 43.2 minutes; once it is spent, the usual practice is to prioritise reliability work over new releases.

Standards and frameworks: Uptime Institute Tier Standard (Tier I–IV), ANSI/TIA-942 (data centre infrastructure), and site reliability engineering practice for SLOs.

ToolsAvailabilitySystem ReliabilityCost of Downtime

Healthcare equipment

For clinical engineering teams the question is whether a device is available and safe when a patient needs it. Programmes are risk-based: life-support and high-acuity equipment gets tighter inspection and faster response than low-risk devices.

MetricUse
Equipment uptimeAvailability of critical devices during scheduled clinical hours
Time to restore (MTTR)Vendor and in-house service performance
Scheduled maintenance completionInspections and PM done on time, by risk class

Standards and frameworks: IEC 60601 (safety of medical electrical equipment), IEC 62353 (recurrent testing after repair), and ISO 14971 (risk management for medical devices). Accreditation bodies set the local requirements for maintenance programmes.

ToolsAvailabilityMTTRFMEA / RPN